Arteche manufactures trip and lockout relays with a wide range of options to met each application requirements. Reliability an performance by default for. Installed in more than countries, Arteche relays are the best choice for applications such as trip high and medium voltage breakers, safety critical logics in. Instantaneous relays contacts change instantaneously from non-working position to working position when its coil is energized, coming back contacts to the.

Author: Daigul Moogutaxe
Country: Namibia
Language: English (Spanish)
Genre: History
Published (Last): 28 May 2017
Pages: 346
PDF File Size: 16.14 Mb
ePub File Size: 19.2 Mb
ISBN: 309-4-37254-694-9
Downloads: 23587
Price: Free* [*Free Regsitration Required]
Uploader: Aralrajas

In order to avoid faulty alarms due to instantaneous supply voltage dips, the drop off time of the relay is delayed over ms so those non-permanent failures of trip supply would not be considered.

ARTECHE, Spain

Trip and lockout relays Trip relays with 2 stable positions for the output contacts. Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply. The output contacts change its position if the relay detects a failure in the continuity of the circuit.

  BAHMANI OSKOOEE PDF

Trip relays with 2 stable positions for the output contacts. Trip relays Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working position when the coil is energized.

Faults will occur when the trip voltage is lost, so the relay drops off in those cases, providing the related signs and alarms. It uses reference signal from GPS Global Positioning System and features wide variety of outputs and time coding standards. Connecting the relay across artedhe trip circuit supply, the equipment is normally energized.

The contacts return to the rest position when the coil is no longer energized. This range includes relay with 4 and 8 contacts, with operating times below 8 ms or 10 ms, depending on the model, and possibility of artevhe reset. Through a small supervision current the whole circuit is supervised, in both positions of the circuit breaker opened or closed.

This range includes relays with 2, 4 and 8 contacts, with operating times from 3 ms to 8 ms, depending on the model. Auxiliary supply circuit supervision relays Auxiliary relay with four changeover contacts, aimed to supervise the failure of trip supply.

  LM317 TO3 PDF

Trip circuit supervision relays For single phase or three phase circuit breakers. The correct state of the circuit is showed with a green LED on the front plate of the relay.

Latching Relays: Arteche – InnoTrans – Product

Instantaneous trip relays, whose contacts change instantaneously from the rest position to the working position when the coil is energized. Depending on which coil is energized, the contacts will change from one position to the other. For single phase or three phase circuit breakers.